ClosedCombined Synopsis/Solicitation
Dept of Defense contract category

AIR COMPRESSOR CHILLER

Dept of Defense · DEPT OF THE ARMY

This notice is not accepting responses (deadline was Sep 15, 2025, 8:00 PM EDT).

Page kept for research and related open opportunities below. For current work in this category, use the related notices or browse hubs.

Response deadline
Sep 15, 2025, 8:00 PM EDT
Posted
Sep 8, 2025
Solicitation
W911S225U1837
Place of performance
Contracting office
W6QM MICC-FT DRUM · FORT DRUM · NY
Source
SAM.gov · updated May 9, 2026

Description

CHILLER UNIT COMPONENTS FOR 760 CFM SULLAIRE AIR COMPRESSOR1 Model AFC44CB-0C41 General Air Products, Inc. Fluid Cooler at 427,538 Btu/Hr total at a flow of 46.4 gpm total with a 5? F approach, 40% propylene glycol solution and a design ambient of 85? F. Coolers will have A350 Johnson controls for fan cycling and 460v/3/60Hz electrical equipment and offer the following features as standard 4 direct drive 1.5 HP propeller fans with vinyl coated fan guards, weather resistant motors with sealed bearings, internal overload protection, and hardware designed for outdoor duty. Access door panels at each fan motor, vent and drain connection and corrosion resistant construction.1 Model FPSBD44A, 3 HP Fluid Pumping Station for 40 PSI and to be wired 460v/3/60Hz with a 120v control circuit. Pumping station to be completely pre-plumbed and pre-wired with TEFC type motors and a NEMA 4 steel control panel. The unit will have a close-coupled centrifugal pump with expansion tank, temperature and pressure gauges, check valves and shut off safety valves plus a steel base as standard. This unit will be a Duplex design.1 Model MVD75, 1.5? 75 degree thermostatic mixing valve.1 TC3060, Trim Cooler, to trim system on days over 85? F ambient.1 Model WV125, 1.25? Trim water modulating valve. The following document provides the requirements and specifications for the chiller unit for 2 Sullaire air compressors. Applicable Documents 1. Standards and Regulations: 2. Additional Documents Requirements 3. General Requirements This section provides the design specification requirements for the B190 compressor chiller unit. a. The chiller unit will need to be sized to provide water cooling to the heat exchangers on a 150 HP, 100 PSI Gardner Denver screw compressor that can produce 760 CFM. i. The compressors are plumbed into an oil cooler for the outgoing compressed air This section provides specific requirements for the B190 compressor chiller unit equipment requested. a. Fluid Fan Bank Cooler i. General Air Products Model AFC44CB-0C41, or equivalent ii. 427,538 Btu/ Hr total at flow rate of 46.4 GPM iii. To be operated with a 40% propylene glycol solution iv. A350 Johnson controls for fan cooling v. 460V/ 3 Ph/ 60 Hz vi. 4 direct drive 1.5 hp propeller fans with fan guards vii. Sealed bearings viii. Internal overload protection ix. Access panels for each motor x. Vent and drain connections b. Duplex Pumping station i. General Air Products Model FPSBD44A, or equivalent ii. 3 HP for 40 PSI iii. 460V/3Ph/60 Hz iv. 120V control circuit v. Pre-plumbed and wired with TEFC motors vi. NEMA 4 control panel vii. Close-coupled centrifugal pump with expansion tank\ viii. Temperature and pressure gauges ix. Check valves and shut-off valves c. 1.5? 75 degree Thermostatic Mixing valve i. General Air Products Model MVD75, or equivalent d. Trim Cooler for days over 85 degF ambient i. General Air Products Model TC3060, or equivalent e. Trim Water Modulating Valve i. General Air Products Model WV125, or equivalent Proposal, Reviews, Drawings, Documentation, and Data

What similar awards have paid

Real federal awards already on the books in a similar lane — so you can size the opportunity, not guess. This is public history, not a bid price, cost estimate, or prediction that you will win.

Typical award size

$25,726

Middle of the pack for similar past awards

Most similar awards fall between $15,532 and $82,742

Lower end$15,532Typical$25,726Higher end$82,742
Based on 108 similar awardsSame industry code (333912)Prime contracts (not umbrella IDVs)

Who has won work like this

Public awardees in this lane — useful for competitor scan or teaming ideas, not a ranked list of “best” firms.

Recent examples

A few of the newest similar awards in our index.

Drawn from official USAspending contract records in our index. Always confirm requirements on the SAM.gov notice before you bid.

Intelligence only — not legal advice or a guarantee of award. Always verify requirements on the official SAM.gov notice. Past award amounts are public history, not a suggested bid or prediction. Notice ID 4d2bb869a0934913936d48ba4a98d632.

Similar open government contracts

More in 333912 →
Federal vendorsMore from Dept of DefenseNAICS 333912PSC 3695Total Small Business