Description
TABLE 1: Water Quality Routine Testing Frequency for Critical Water, Utility Water, AER Final Rinse, and Steam Condensate for each (Brooklyn and Manhattan) of the Medical Centers will be: Water Quality Measurement Source Sampling Site(s) # of Samples per event Sampling Frequency # of Samples per year MANHATTAN & BROOKLYN pH Critical Water After the last treatment step at the water generation system At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 Conductivity Critical Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Monthly 12 Total Alkalinity Critical Water After the last treatment step, storage tanks At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 Total Hardness Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Monthly 24 BROOKLYN Bacteria Critical Water Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 7 Monthly 84 Endotoxin Critical Water Water storage tank Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 8 Monthly 96 MANHATTAN Bacteria Critical Water Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4NY - will eventually have 4 ultrasonic Ok Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinfector #3 15 Monthly 156 Endotoxin Critical Water Water storage tank Loop out point Loop return point Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4 Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinfector #3 16 Monthly 168 MANHATTAN & BROOKLYN Total Organic Carbon (TOC) Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Quarterly 8 Ionic Contaminants Aluminum Chloride Copper Iron Manganese Nitrate Phosphate Sulfate Silicate Zinc Critical Water After the last treatment step At the point the distribution loop enters the processing area or first POU on the distribution loop 2 Quarterly 8 pH Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Conductivity Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Total Alkalinity Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Total Hardness Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 BROOKLYN Bacteria Utility Water Each location of point-of-use in department (subject to change): Decon Sink Scope Sink Unity Ultrasonic Washer-Disinfector #1 Washer-Disinfector #2 5 Quarterly 20 MANHATTAN Bacteria Utility Water Each location of point-of-use in department (subject to change): Decon Sink #1 Decon Sink #2 Decon Sink #3 Decon Sink #4 Scope Sink #1 Scope Sink #2 Caviwave PRO Ultrasonic #1 Caviwave PRO Ultrasonic #2 Caviwave PRO Ultrasonic #3 Caviwave PRO Ultrasonic #4 Washer-Disinfector #1 Washer-Disinfector #2 Washer-Disinvector #3 13 Quarterly 44 Total Organic Carbon (TOC) Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 Ionic Contaminants Aluminum Chloride Copper Iron Manganese Nitrate Phosphate Sulfate Silicate Zinc Utility Water At the point the distribution loop enters the processing area or first POU on the distribution loop 1 Quarterly 4 BROOKLYN pH Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Conductivity Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Total Alkalinity Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Total Hardness Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Ionic Contaminants Steam Steam Sterilizer Cooler Sample Port 1 Quarterly 4 Bacteria Automated Endoscope Reprocessor Medivator #27 Right Basin Medivator #27 Left Basin Medivator #28 Right Basin Medivator #28 Left Basin 4 Monthly 48 Endotoxin Automated Endoscope Reprocessor Medivator #27 Right Basin Medivator #27 Left Basin Medivator #28 Right Basin Medivator #28 Left Basin 4 Monthly 48 MANHATTAN pH Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Conductivity Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Total Alkalinity Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Total Hardness Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Ionic Contaminants Steam Steam Sterilizer Cooler Sample Port 2 Quarterly 8 Bacteria Automated Endoscope Reprocessor Medivators #1 Right Basin Medivators #1 Left Basin Medivators #2 Right Basin Medivators #2 Left Basin Medivators #3 Right Basin Medivators #3 Left Basin 6 Monthly 72 Endotoxin Automated Endoscope Reprocessor Medivators #1 Right Basin Medivators #1 Left Basin Medivators #2 Right Basin Medivators #2 Left Basin Medivators #3 Right Basin Medivators #3 Left Basin 6 Monthly 72
What similar awards have paid
Real federal awards already on the books in a similar lane — so you can size the opportunity, not guess. This is public history, not a bid price, cost estimate, or prediction that you will win.
Typical award size
$59,100
Middle of the pack for similar past awards
Most similar awards fall between $20,551 and $173,081
Who has won work like this
Public awardees in this lane — useful for competitor scan or teaming ideas, not a ranked list of “best” firms.
- 1WASHINGTON SUBURBAN SANITARY COMMISSION6 awards$78.43M
- 2CITY OF OAK RIDGE1 award$46.15M
- 3NORTHEAST OHIO REGIONAL SEWER DISTRICT2 awards$10.37M
- 5CLEAR LAKE CITY WATER AUTHORITY1 award$5.71M
- 6CITY OF COCOA1 award$5.61M
- 7CITY OF WILDWOOD CITY HALL1 award$4.85M
- 8SUN COAST RESOURCES, LLC1 award$4.69M
Recent examples
A few of the newest similar awards in our index.
- FLUID SOLUTIONS LLCSep 30, 2025Department of State$86,173Source
- DC WATER & SEWER AUTHORITYSep 30, 2025Department of the Treasury$1.43MSource
- AL-SOBUL AL-MODHEAA COSep 30, 2025Department of State$247,500Source
- AMERICAN VET SOLUTIONS INCSep 30, 2025Department of Homeland Security$25,200Source
- CASIMIRO, ORESTES, ROSANESSep 30, 2025Department of State$43,871Source
- WATER & ENERGY SYSTEMS TECHNOLOGY, INCSep 30, 2025Department of Veterans Affairs$141,840Source
Drawn from official USAspending contract records in our index. Always confirm requirements on the SAM.gov notice before you bid.
Intelligence only — not legal advice or a guarantee of award. Always verify requirements on the official SAM.gov notice. Past award amounts are public history, not a suggested bid or prediction. Notice ID 26b816e0b5754310aeb701f44c9e49e5.