Z1DA--Improve Central Utility Plant VAMC Las Vegas, NV Project 593-22-350
Veterans Affairs, Department of · VETERANS AFFAIRS, DEPARTMENT OF
This notice is not accepting responses (deadline was Dec 3, 2025, 1:00 PM EST).
Page kept for research and related open opportunities below. For current work in this category, use the related notices or browse hubs.
- Response deadline
- Dec 3, 2025, 1:00 PM EST
- Posted
- Nov 18, 2025
- Solicitation
- 36C26126R0004
- Set-aside
- SDVOSB
- Place of performance
- N. Las Vegas, NV, USA
- Contracting office
- 261-NETWORK CONTRACT OFFICE 21 (36C261) · MATHER · CA
- Source
- SAM.gov · updated Jul 5, 2026
Description
OPPORTUNITIES DESCRIPTION Construction Service for Project No. 593-22-350, Improve Central Utility Plant at VA Medical Center Las Vegas, NV. This is a pre-solicitation announcement only. Solicitation documents will be available on or around January 7, 2026. The solicitation will contain all necessary proposal instructions. This requirement is a total set-aside for a Service Disabled Veteran Owned Business (SDVOSB). The applicable North American Industry Classification System (NAICS) Code is 236220, Commercial and Institutional Building Construction, and the small business size standard is $45M. In Accordance With (IAW) VA Acquisition Regulation (VAAR) 836.204(g) Disclosure of the magnitude of construction projects is anticipated between $5,000,000.00 and $10,000,000.00. Questions regarding this pre-solicitation must be sent in writing to christopher.whipple@va.gov Project Purpose: The purpose of this project is to perform the following: Equipment Replacement, Modification, and Integration: The GC shall make themselves intimately familiar with full scope as defined in this scope of work, construction drawings, and specifications. This work includes but is not limited to: Replacement of the heat recovery system in the boiler room. Replace the existing water softener copper piping with new stainless steel piping and add polisher for a redundant system. Reconfigure the non-return valve at the top of boiler #3 into a horizontal configuration. Replace the existing corroded condensate return/surge tank with a new stainless steel tank. Extend/connect catwalk above boiler room for access to air handlers. Replace windows with operable louvers in Boiler room above overhead door (interlock to close with fire alarm activation). Automate back-up pumps located in Building 5 basement Controls in Building 2 boiler room and connect to existing BMS/JCI system for controlling and status display. Automate fuel oil system located in Building 3 and locate controls in Building 2 boiler room. Integrate fuel tank system to Hayz Cleveland controls in Building 2 boiler room (9 tanks total only 4 tanks are currently showing on the system). Separate 2 of the 5 condenser pumps onto their own dedicated power source bank (MCC). Replace 5 existing condenser pumps with high efficiency double impeller or raise the cooling towers and extend screen wall around cooling tower yard. The A/E shall determine the best solution. Install secondary water supply to cooling towers from 10 waterline at east side of CUP. Upgrade facility-wide Lutron lighting controls as needed for single point monitoring in CUP control room. Add ladders/stairs and extend catwalks in chiller room for improved access to serviceable equipment. Replace (5) failing existing cooling tower Variable Frequency Drives (VFD) with new like-for-like. Replace (5) failing existing chilled water pump VFDs with new like-for-like Replace (5) existing chilled water pumps with new high efficiency domestically sourced pumps with readily available domestic parts to match the new condenser pumps. Replace (3) failing existing industrial Water pump VFDs with new like-for-like Replace (3) existing industrial water pumps with new like-for-like. Offerors are strongly urged to attend the site visit prior to submitting their proposals to evaluate the extent of the project requirements. The period of performance for this project is 360 calendar days from when the notice to proceed (NTP) is issued. The work will be accomplished at VAMC Las Vegas, located at 6900 North Pecos Road, North Las Vegas, NV 89086. (END OF OPPORTUNITIES DESCRIPTION)
What similar awards have paid
Real federal awards already on the books in a similar lane — so you can size the opportunity, not guess. This is public history, not a bid price, cost estimate, or prediction that you will win.
Typical award size
$886,627
Middle of the pack for similar past awards
Most similar awards fall between $201,693 and $3.78M
Who has won work like this
Public awardees in this lane — useful for competitor scan or teaming ideas, not a ranked list of “best” firms.
- 1WELCH CONSTRUCTION INC.7 awards$63.34M
- 2SERVIAM CONSTRUCTION LLC19 awards$63.00M
- 3RBVETCO, LLC14 awards$57.90M
- 4AC JV ONE LLC3 awards$53.64M
- 5SEMPER TEK INC8 awards$51.54M
- 6BRIDGER RICHARD JV LLC1 award$47.28M
- 7ESA SOUTH, INC.1 award$46.13M
- 8AMERIFIELD JV LLC1 award$45.60M
Drawn from official USAspending contract records in our index. Always confirm requirements on the SAM.gov notice before you bid.
Intelligence only — not legal advice or a guarantee of award. Always verify requirements on the official SAM.gov notice. Past award amounts are public history, not a suggested bid or prediction. Notice ID d220b4c5bd46445aab60c40b5160273f.